Pharmacology Instruments
Ointment slabs 12″x12″in minimum 8mm thickness Heavy weight glass squares provide a hard nonporous surface for incorporating compounds into ointment bases. The roughened bottom minimizes movement. Smooth beveled edges resist chipping and make handling easier.
Download:b1
Related products
-
Broome Restrainers
These popular Broome Restrainers provides fast and easy animal insertion. The cylindrical design of these Restrainers solves the problem of the rodents turning once they are introduced into the Restrainer.
To place the animal into the Restrainer, loosen white Derlin nose piece and grasp the animal by the tail. Slide the animal into the Restrainer by pulling its tail along the open groove until the animal is completely enclosed in the cylinder. Then slide the nose piece into the groove on the opposite side of the Restrainer and place it up to the nose of the animal.
Download:Broome Restrainers
-
Single Tissue Bath 2
The walls of this bath are made of heavy, transparent plastic, so that the specimen can be
consultant and easily observed. The walls are 6mm thick. The tank measureThe two sides of the bath are extended to form a stand. The heating control housing is made of white plastic, offering the double advantage of being corrosion proof and an excellent electrical insulator from the heater.
Download:Single Tissue Bath 2
-
Student Single Tissue Bath
Capacity: 3.6 Liter with decent look
Heaters 120 Watts
A float switch provides a safety cut off should the water level fall
below the minimum permitted level,
Two modes for solution replacement emptying and filling
Each tissue chamber has an adjustable gas diffuser for oxygenation and
push toggle on the front of the unit control the filling and emptying of the
tissue chambers via toggle switch.
Perspex sheet wall thickness 8mm
Magnetic Stirrer for uniform temperature
The control system provides an LED display
Inner Tissue Bath Standard 25ml Capacity Qty 1 with each Bath
Detachable Stem Tissue Vessel, supplied as standard,
for increased convenience when changing tissue vessels.
(The tissue chamber portion of the tissue vessel can be removed
without disturbing the stem or disconnecting the tubing for the warmed
perfusate and drainage.
Inner tissue bath Pyrex Material Graduated 25 ml Capacity
O ring provide 2 set
Warming Coil Round/Curve flat type
Power: 220 Voltages
Download:Student Single Tissue Bath
-
Isolated Organ and Tissue
This Heated Water Bath is for the most demanding research work.
It has two heaters having 250 watts of combined power.
The temperatur is automatically controlled by a sensitive thermistor
in a metal tube inside the bat to hold the bath water
temperature has stabilized. A magnetic stirrer in the bottom of the
tank slowly circulates the water to ensue uniform temperature.
These heaters are mounted through the front of the tank near the
bottom and extend 100 mm (4 in) into it. The desired temperature of
the Water Bath is set by a dial on the front panel that is graduated
from 15o to 45o C in 5o increments.
Two on/off switches and indicator lamps, one for power and the other
for the magnetic stirrer are on the front panel.
Download:Isolated Organ and Tissue

Reviews
There are no reviews yet.